beautypg.com

Nitrogen, Ht4001 without slave, Pac620 torch – standard consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 113: Mild steel – nitrogen plasma

background image

11-96

5-22

HT4001

Instruction Manual

Notes:

• Minimum N

2

inlet supply pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.

• Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
• N

2

flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.

• Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you

are cutting.
Note: If arc does not transfer when set at twice the torch standoff (in the case of thick metal being cut at high
current), gradually lower the initial height of the torch until transfer occurs.

HT4001 without Slave

PAC620 Torch – Standard Consumables

Mild Steel – Nitrogen Plasma

Retaining Cap

020579 (Vect)

020246 (Vesp)

Nozzle

020089

(.120 in/3 mm)

020084

(.166 in/4.2 mm)

Swirl Ring

020039 (cw)

020042 (ccw)

Electrode

020082

Water Tube – Standard

020990

120466 – CE (Vect)
120467 – CE (Vesp)

E

N

G

L

I

S

H

M

E

T

R

I

C

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(in)

(mm)

(%)

(%)

(%)

(in)

(mm)

(ipm)

(mm/min)

.035

.889

30

30

45

125

260

1/8

3

450

11430

.075

1.91

30

30

45

130

260

1/8

3

300

7620

1/8

3.18

30

30

45

135

260

1/4

6

200

5080

1/4

6.35

30

30

45

145

260

5/16

8

145

3690

1/8

3.18

45

45

62

140

300

1/4

6

175

4450

1/4

6.35

45

45

62

140

360

1/4

6

145

3690

3/8

9.53

45

45

62

145

360

1/4

6

125

3180

1/2

12.7

45

45

62

150

400

1/4

6

95

2420

3/4

19.1

45

45

62

150

400

5/16

8

50

1270

1

25.4

45

45

62

155

400

3/8

10

30

760

.120"

260A max.

.166"

400A max.

Arc Volts

(V)

Arc

Current

(A)

Torch

Standoff

Travel Speed

Nozzle

Material

Thickness

Water Flow

Setting

Test Preflow

Rate

Test Cut Flow

Rate

(N

2

)

(N

2

)

(mm)

(%)

(%)

(%)

(mm)

(mm/min)

3 mm

260A max.

6

30

30

45

145

260

8

3840

6

45

45

62

140

360

6

4660

8

45

45

62

145

360

6

3420

10

45

45

62

145

360

6

3060

12

45

45

62

150

400

6

2580

15

45

45

62

150

400

6-7

2000

20

45

45

62

150

400

8

1190

25

45

45

62

155

400

10

790

4.2 mm

400A max.

Arc Volts

(V)

Arc

Current

(A)

Torch Standoff

Travel Speed

Nozzle

Material

Thickness

Water Flow

Setting