Power supply connections (cont.) – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 71
INSTALLATION
4-18
HT4001
Instruction Manual
Power Supply Connections (cont.)
Timer/Counter Cable – PS to Timer/Counter
Pass the timer/counter cable through one of the 2" bushings in the lower rear of the HT4001 power supply
and connect to TB3. TB3 is located on the inside rear wall of the power supply.
PS TB3
TIMER/CNTR
END
COLOR
END
DESCRIPTION
53
Wht
1
Starts & Arc Time
52
Black
2
Starts & Arc Time
8
Drain
3
Drain
50
Red
15
Error Counter
51
Black
16
Error Counter
3
Drain
12
Drain
IHS Interface Cable – PS to IHS
See pages 4-32 through 4-35 for remaining IHS connections.
PS
IHS MODULE
END
COLOR
END
DESCRIPTION
1
Red
1
IHS Complete Signal
4
Black
4
IHS Complete Common
8
Shield
Drain
2
Green
2
Upper Limit Switch Signal
5
Black
3
Upper Limit Switch Common
9
Shield
5
Drain
11
Blk
9
AC Power
14
White
8
AC Power
7
Shield
AC Drain
7
Key
11
PS End
12
1X9
8X1
IHS End
PS End
Tmr/Cntr End
11X1
Part No.
Length
023789
10 ft (3 m)
023790
25 ft (7.5 m)
023791
50 ft (15 m)
Part No.
Length
023792
75 ft (23 m)
023793
100 ft (30.5 m)
023794
150 ft (46 m)
Part No.
Length
023859
25 ft (7.5 m)
023860
50 ft (15 m)
023861
75 ft (23 m)
Part No.
Length
023862
100 ft (30.5 m)
023863
150 ft (46 m)
023864
200 ft (61 m)