Nitrogen, Ht4001 without slave, Pac620 torch – beveling consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 119: Aluminium – nitrogen plasma

11-96
5-28
HT4001
Instruction Manual
Notes:
• Minimum N
2
inlet supply pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.
• Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
• N
2
flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.
• Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you are
cutting.
Note: If arc does not transfer when set at twice the torch standoff (in the case of thick metal being cut at high
current), gradually lower the initial height of the torch until transfer occurs.
HT4001 without Slave
PAC620 Torch – Beveling Consumables
Aluminium – Nitrogen Plasma
Retaining Cap
120390 (Vect)
120391 (Vesp)
Nozzle
120386
(.120 in/3 mm)
120387
(.166 in/4.2 mm)
Swirl Ring
020039 (cw)
020042 (ccw)
Electrode
020968
Water Tube – N
2
Bevel
020991
120470 – CE (Vect)
120471 – CE (Vesp)
E
N
G
L
I
S
H
M
E
T
R
I
C
Test Preflow
Rate
Test Cut Flow
Rate
(N
2
)
(N
2
)
(in)
(mm)
(%)
(%)
(%)
(in)
(mm)
(ipm)
(mm/min)
.035
.889
30
30
45
120
240
1/8
3
520
13200
.075
1.91
30
30
45
125
240
1/8
3
345
8760
1/8
3.18
30
30
45
130
260
3/16
5
230
5840
1/4
6.35
30
30
45
140
260
1/4
6
170
4320
1/8
3.18
55
55
62
140
280
1/4
6
220
5590
1/4
6.35
55
55
62
150
320
1/4
6
165
4190
3/8
9.53
55
55
62
150
340
1/4
6
130
3300
1/2
12.7
55
55
62
150
360
1/4
8
110
2800
3/4
19.1
55
55
62
150
380
5/16
8
60
1520
1
25.4
55
55
62
165
380
3/8
10
35
890
.166"
400A max.
Arc
Current
(A)
Torch
Standoff
Travel Speed
.120"
260A max.
Nozzle
Material
Thickness
Water Flow
Setting
Arc Volts
(V)
Test Preflow
Rate
Test Cut Flow
Rate
(N
2
)
(N
2
)
(mm)
(%)
(%)
(%)
(mm)
(mm/min)
3 mm
260A max.
6
30
30
45
140
260
6
4500
6
55
55
62
150
320
6
4340
8
55
55
62
150
340
6
3720
10
55
55
62
150
340
6
3220
12
55
55
62
150
360
6
2900
15
55
55
62
150
360
6-7
2330
20
55
55
62
155
380
8
1430
25
55
55
62
160
380
10
930
Arc
Current
(A)
Torch Standoff
Travel Speed
4.2 mm
400A max.
Nozzle
Material
Thickness
Water Flow
Setting
Arc Volts
(V)