beautypg.com

Optional power supply connections -36, Optional power supply connections – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 89

background image

INSTALLATION

4-98

4-36

HT4001

Instruction Manual

Optional Power Supply Connections

Hold cable – PS to Second HT4001 Power Supply
When using a multi-torch system, the hold cable interfaces the two HT4001 power supplies. Make
connections at TB3 on both supplies. TB3 is located on the inside rear wall of the HT4001 power supply.

PS1

PS2

END

COLOR

END

FUNCTION

86

Black

86

Hold signal

87

Red

87

Hold common

PE

Shield

GND

Hold shield

Slave Cable – PS to H401 or H601 Power Supply

Positive Lead – PS to H401 or H601 Power Supply

Negative Lead – PS to H401 or H601 Power Supply

Positive Lead – PS to Work Table (Additional lead needed when using slave)

Negative Lead – PS to RHF Console (Additional lead needed when using slave)

When using more than 400 amps of cutting current, a slave power supply must be used with the HT4001
power supply. See Appendix A for details.

29

30

31

32

33

34

Black

Red

GND

Black

Red

GND

Part No.

Length

023340

15 ft (4.5 m)

023341

25 ft (7.5 m)

023342

50 ft (15 m)

Part No.

Length

023343

100 ft (30.5 m)

023344

150 ft (46 m)