2.0 Installation and Operation Overview

RN-8200 Reference Manual

Page 2-6

2.2.4 RJ-45 LAN Interface Cabling

This port is used to access the RN-8200 Embedded Web Server via TCP-IP
from a host computer or network.

Cable type:

RJ-45 Crossover for direct computer to RN-8200 control
RJ-45 Straight through for Network to RN-8200 control

Recommended Maximum Length: 329 feet

Crossover Cable

Standard Patch Cable

2.2.5 Relay Control Ports

The RN relay ports shown above, consist of 4,
single-pole, normally open relays grouped as 2
sets with each set sharing a common leg. The
internal relay configuration is shown below and a
typical application is shown to the right.

C 1

2

C 3

4

Internal Configuration

RELAY OUTPUT

C

C

1 2

3 4

RED

WHT

BLK

RED

WHT

BLK

Sample Application: Da-Lite Screen Control

Setting Relay 1 momentarily drives both screens up
Setting Relay 2 momentarily drives both screens down