2 tuner mpe/ip configuration menu – Comtech EF Data CMR-6000 Manual User Manual
Page 97

Digicast Media Router S2 Receiver CMR-6000
Revision 1
Device Management via User Interfaces
MN-CMR6000-IOM
4-67
4.4.11.2
Tuner MPE/IP Configuration Menu
A configured PID value in hexadecimal is required for MPE/IP data to be extracted from the transport
stream and sent to the CPU. Once a valid PID value is configured, and data is found on a transport
stream, the data is decapsulated and delivered to the Ethernet port. A value of 0x1FFF is disabled.
Name
The name of the route.
PID
The PID value in hexadecimal format.
Mode
MPE/IP or DVB-TS.
VLAN
Options are None, All, or 1 to 4094.
Destination IP
A valid destination IP address if mode is DVB-TS.
Port
A valid port if mode is DVB-TS.