Comtech EF Data CRS-400 User Manual

Page 85

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Remote Control MN/CRS400.IOM

69

Parameter
Type

Command
(controller
to target)

Argument
count

Description of arguments

Note: All arguments are ASCII numeric codes between 48

and 57.

Responses
to
Command
(target to
controller)

Query
(controller
to target)

Response to Query
(target to controller)

Audio Alarm
Mask

AAM= 1

byte,

numerical

Command or Query.
Sets or queries the audio alarm mask:
0 = No faults masked (audio enabled in response to

any fault)

1 = Switch faults masked
2 = Modem faults masked
3 = All faults masked (audio never enabled)

AAM=
AAM?
AAM*
AAM#

AAM? AAM=x

(see description of arguments)

Retrieve next
5 unread
Stored Events

n.a.

79 bytes

Query only.
Returns the oldest 5 Stored Events which have not yet
been read over the remote control. Reply format:
{CR}sub-body{CR}sub-body{CR}sub-body{CR}sub-
body{CR}sub-body, where sub-body =
ABCddmmyyhhmmss

A is the fault indicator:
F = Fault,
C = Clear,
I = Info

B is the faulting/clearing Unit:
1-8 = Mod (1-8)
9 = Redundant Mod
A-H = Demod (1-8)
I = Redundant Demod
J = Switch
K = Power on/off, or log cleared (Info events)

C is the fault code number , as defined:
Switch: 1 through D, the same as FLT? string.
Modem: 0
Info: 0= Power off, 1= Power on, 2= Log cleared.

ddmmyy hhmmss indicates the date & time of the
event.

If there are no new events, the unit replies with RNE? If
fewer than 5 events remain, the last positions are
padded with zeros.

n.a. RNE?

RNE=[cr]
ABCddmmyyhhmmss[cr]
ABCddmmyyhhmmss[cr]
ABCddmmyyhhmmss[cr]ABCddmmyyhhmmss[cr]ABCddmmyyhhmmss
(see description of arguments)