Comtech EF Data CRS-400 User Manual
Page 85
CRS-400 1:8 Redundancy Switch
Revision 0
Remote Control MN/CRS400.IOM
69
Parameter
Type
Command
(controller
to target)
Argument
count
Description of arguments
Note: All arguments are ASCII numeric codes between 48
and 57.
Responses
to
Command
(target to
controller)
Query
(controller
to target)
Response to Query
(target to controller)
Audio Alarm
Mask
AAM= 1
byte,
numerical
Command or Query.
Sets or queries the audio alarm mask:
0 = No faults masked (audio enabled in response to
any fault)
1 = Switch faults masked
2 = Modem faults masked
3 = All faults masked (audio never enabled)
AAM=
AAM?
AAM*
AAM#
AAM? AAM=x
(see description of arguments)
Retrieve next
5 unread
Stored Events
n.a.
79 bytes
Query only.
Returns the oldest 5 Stored Events which have not yet
been read over the remote control. Reply format:
{CR}sub-body{CR}sub-body{CR}sub-body{CR}sub-
body{CR}sub-body, where sub-body =
ABCddmmyyhhmmss
A is the fault indicator:
F = Fault,
C = Clear,
I = Info
B is the faulting/clearing Unit:
1-8 = Mod (1-8)
9 = Redundant Mod
A-H = Demod (1-8)
I = Redundant Demod
J = Switch
K = Power on/off, or log cleared (Info events)
C is the fault code number , as defined:
Switch: 1 through D, the same as FLT? string.
Modem: 0
Info: 0= Power off, 1= Power on, 2= Log cleared.
ddmmyy hhmmss indicates the date & time of the
event.
If there are no new events, the unit replies with RNE? If
fewer than 5 events remain, the last positions are
padded with zeros.
n.a. RNE?
RNE=[cr]
ABCddmmyyhhmmss[cr]
ABCddmmyyhhmmss[cr]
ABCddmmyyhhmmss[cr]ABCddmmyyhhmmss[cr]ABCddmmyyhhmmss
(see description of arguments)