beautypg.com

Crs-280 if redundancy switch specifications, 2 crs-280 if redundancy switch specifications, 2 crs-280 if r – Comtech EF Data CRS-400 User Manual

Page 25

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Introduction

MN/CRS400.IOM

9

1.4.2 CRS-280 IF R

EDUNDANCY

S

WITCH

S

PECIFICATIONS

Characteristic Requirement

Tx/Rx Operating Frequency

50 to 180 MHz

Return Loss

18 dB return loss into 75

(50

optional)

Tx to Tx Channel Isolation

> 50 dB

Rx to Rx Channel Isolation

> 50 dB

Tx to Rx Channel Isolation

> 60 dB

Number of Uplinks

1 to 8 traffic mods/demods

Transmit IF Loss

< 1.5 dB over operating frequency

Receive IF Loss

< 5 dB over operating frequency

Tx / Rx Connectors

BNC female

L-Band IF Switch

Number of Downlinks

1 to 8 traffic units

Powering of IF Switch

From the CRS-400 chassis for 70 / 140 MHz or L-Band
Switch