background image

CRS-400 1:8 Redundancy Switch

Revision 0

Installation and Setup

MN/CRS400.IOM

21

2.6.6 A

UXILIARY

S

ERIAL

C

ONNECTOR

/ P

ASS

-T

HROUGH

This connector is used for switch remote control of each SDM-2020 modulator or
demodulator. This remote communication is fixed at a rate 19200 Baud with 7-E-2
character format. Ensure that each mod/demod is set for EIA-485 4-wire communications
and the matching protocol and baud rate.

The pinout for EIA-485 communication at the switch is the same as the remote control on
the SDM-2020 modems. Table 2-5 provides the pinout information.

Table 2-5 Auxiliary Serial Connector/Pass-Through, Cable # PL/9195-1

CRS-400

9-Pin D

Male Description

VO

9

EIA-485 Receive Data B

I

8

EIA-485 Receive Data A

I

5

EIA-485 Transmit Data B

O

4

EIA-485 Transmit Data A

O

1 Ground

2 Not

connected

3 Not

connected

6 Not

connected