CRS-400 1:8 Redundancy Switch

Revision 0

Introduction

MN/CRS400.IOM

2

The CRS-400 is fully modular in construction. All replaceable modules insert into slots in
the rear. This includes the Controller, Power Supply Units (PSU), Traffic Modem
Interface (TMI) and the Redundant Modem Interface (RMI). Power consumption is
below 25 W for a fully populated switch, so no fan cooling is required.

The CRS-400 incorporates the following key reliability features:

Twin, independent, AC power supplies

Maintains normal traffic paths, error free, when AC power is removed

Note: Redundant Modulator/Demodulator traffic returns to normal traffic path if power is lost

Figure 1-1 CRS-400 Block Diagram with Modems and CRS-280 IF Switch

The function of the CRS-400 Redundancy Switch is depicted in Figure 1-1. User data en-
ters and exits the switch at the left hand side of the diagram, while IF leaves and enters
from the right. The data and clock signals to and from a traffic modulator/demodulator
are routed through a TMI, via a set of relays. There are up to 8 TMIs in the switch,
labeled 1 through 8 in the figure. The relays in the TMI are arranged so that the
unpowered state connects the data signals directly through to the traffic
modulator/demodulator. If the power supplies to the system are lost, or if a TMI carrying
traffic is removed, traffic is not interrupted. In normal circumstances, when the redundant
modulator/demodulator is not in service, no data is carried through the CRS-400
backplane – all data is routed through the TMI.

Traffic

Modem

Switches

(TMI)

&

Redundant

Modem

Switch

(RM I)

1

2

3

4

5

6

7

8

Redundant

1

2

3

4

5

6

7

8

Modem 1

Modem 2

Modem 3

Modem 4

Modem 5

Modem 6

Modem 7

Modem 8

CRS-280

IF

Switch

(Optional)

Modulator

Demodulator

Or

Modem Redund

To

User

Equipm ent

To

Up

Converters

From

Down

Converters

CRS-240

Power Supply

CRS-240

Power Supply

CRS-230

Controller

Remote Control
To All M odem s

IF Switch
Control

System Alarms

1

2

3

4

5

6

7

8

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

Redundant

CRS-400

Front Panel Keypad,

LCD and LED Display

CRS-400.ppt

Remote

Pass-Thru