background image

CRS-400 1:8 Redundancy Switch

Revision 0

Installation and Setup

MN/CRS400.IOM

19

Pin Description

16 BU Demod Replaces Traffic Demod “N”, Bit 2 of 3 – NO Contact

3

BU Demod Replaces Traffic Demod “N”, Bit 3 of 3 – NO Contact

15 Unused Relay – NO Contact

2

Unused Relay – NO Contact

14 Unused Relay – NO Contact

1

Common contact for pins 3-6 and 15-18

* Note: Mod/demod Select 0-3 represent the binary address of the Mod/Demod.

2.6.4 IF S

WITCH

C

ONTROL

C

ONNECTOR

The IF Switch Control connector should be cabled directly to the corresponding
connector on the CRS-280 IF Switch, if used. This supplies power to the CRS-280, along
with the logic interface to drive the currently selected traffic mod/demod, and to decide
whether the system is in bridged or back-up mode. The CRS-280 must perform the same
bridging and backing up functions to the transmit and receive IF signals to match what
the CRS-400 does to the terrestrial data signals. Table 2-3 provides the pinout
information.

Table 2-3 IF Switch Control Connector, 25-Pin D Type Male

Pin # Condition

16

Enable

5 Clock

17 Serial

Data

4 Mod_Backup

8 Demod_Backup

3 Rev_Bit0, (for PCA hardware revision control)

18 Rev_Bit1

6 Rev_Bit2

19 Rev_Bit3

7 Product_ID_Bit0, (for IF switch identification)

20 Product_ID_Bit1

21 IF Switch Present