beautypg.com

Connecting the cables, Hssi connection, 9 connecting the cables – Comtech EF Data CRS-400 User Manual

Page 42: 1 hssi connection, Table 2-10 crs-400 to sdm-2020 data connection, 1 hssi c, Onnecting the, Ables

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Installation and Setup

MN/CRS400.IOM

26

2.9 C

ONNECTING THE

C

ABLES

WARNING

Ensure that all power to the equipment is off.

All Mods/Demods must be the same model and contain the same software revision so
that the Redundant Mod/Demod can properly mimic all traffic Mods/Demods.

2.9.1 HSSI C

ONNECTION

1

Connect HSSI data cables between each traffic Mod/Demod and TMI card.

2

Connect a HSSI data cable between the redundant Mod/Demod and the RMI card.

3

Replace any unused cards with blank panels.

4

Connect the multidrop cable (PL/WR9212-1) from the Pass-Through connector to each
SDM-2020 remote port.

5

Do not connect the IF ports at this time.

6

Apply power to the Mods/Demods only.

Table 2-10 lists connections made between the CRS-400 and SDM-2020 units.

Table 2-10 CRS-400 to SDM-2020 Data Connection

From To

SDM-2020

Switch Connectors

Mod Only

Demod Only Mod + Demod

Future

TMI J5

(User)

J6

J7

-

J3

-

-

-

J3

-

J3, Mod

J3 Demod

RMI J6

J7

J3

-

-

J3

J3, Mod

J3, Demod

Controller Remote

(User)

Remote Pass-Through

IF Sw Control

System Alarms (User)

-

J1

-

-

-

J1

-

-

-

J1

-

-