beautypg.com

Configuring the mods/demods – firmware versions, 10 configuring the mods/demods – firmware versions, 10 c – Comtech EF Data CRS-400 User Manual

Page 43: Onfiguring the, Emods, Irmware, Ersions

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Installation and Setup

MN/CRS400.IOM

27

2.10 C

ONFIGURING THE

M

ODS

/D

EMODS

– F

IRMWARE

V

ERSIONS

For correct operation of the CRS-400, the Mods/Demods must have
the following Firmware versions installed:

Minimum Revision

Feature CRS-400 SDM-2020

Mod

SDM-2020
Demod

Future Future

HSSI

M&C Firmware
Ver 8.1.6

M&C Firmware
Ver 22.2.1

75 Ohm Data Ver xxx

Backplane xxx

M&C Firmware
newer than
April 2001

M&C Firmware
newer than
April 2001

IMPORTANT

If the Mods/Demods do not meet this requirement, please contact the factory.


1

Configure these parameters for the SDM-2020 Mod/Demod remote control interfaces:

EIA-485:

4-wire

Rate:

19200

Baud

Format: 7 Data Bits, Even Parity, 2 Stop Bits ( 7-E-2 )

Note: These values are the default settings for the SDM-2020
Utility/System

menu,

REMOTE

BAUD

RATE/PARITY

settings.

Mod

Remote Address: Positions 1 through 8, set Addresses 1 through 8,

with

the

Redundant

Modulator

at

Address

9

Demod

Remote Address: Positions 1 through 8, set Addresses 11 through 18,

with

the

Redundant

Demodulator

at

Address

19

The switch is now ready for the next procedure, Applying Power to the Switch.