For correct operation of the CRS-400, the Mods/Demods must have
the following Firmware versions installed:
Minimum Revision
Feature CRS-400 SDM-2020
Mod
SDM-2020
Demod
Future Future
HSSI
M&C Firmware
Ver 8.1.6
M&C Firmware
Ver 22.2.1
75 Ohm Data Ver xxx
Backplane xxx
M&C Firmware
newer than
April 2001
M&C Firmware
newer than
April 2001
IMPORTANT
If the Mods/Demods do not meet this requirement, please contact the factory.
1
Configure these parameters for the SDM-2020 Mod/Demod remote control interfaces:
EIA-485:
4-wire
Rate:
19200
Baud
Format: 7 Data Bits, Even Parity, 2 Stop Bits ( 7-E-2 )
Note: These values are the default settings for the SDM-2020
Utility/System
menu,
REMOTE
BAUD
RATE/PARITY
settings.
Mod
Remote Address: Positions 1 through 8, set Addresses 1 through 8,
with
the
Redundant
Modulator
at
Address
9
Demod
Remote Address: Positions 1 through 8, set Addresses 11 through 18,
with
the
Redundant
Demodulator
at
Address
19