The CRS-280 provides complete isolation of the IF signals. The redundant Mod/Demod
IF signals are routed to the traffic Mod/Demod IF path when the RMI is online.
Once connected, the CRS-400 automatically senses the presence of the CRS-280. The
CRS-400, upon switching, leaves the offline modulator with its RF on, and the CRS-280
switch relays isolate any undesired signals.
1
Connect the CRS-280 to the CRS-400 with a 25-pin control cable.
2
Refer to Table 2-11 for a complete listing of the CRS-280 IF connections.
3
Connect the Transmit and Receive IF of each Mod/Demod to the CRS-280 with the correct IF
cables.
The same IF connections are used between the CRS-280 and all modems as shown in
Table 2-11.
Table 2-11 CRS-280 IF Switch Connections
From CRS-280
To Other
To Modulator
From CRS-280
To Demodulator
Tx BU
-
Tx IF, Ch Bu
Rx1
Rx IF, Ch1
Tx1
-
Tx IF, Ch1
Rx2
Rx IF, Ch1
Tx2
-
Tx IF, Ch2
Rx3
Rx IF, Ch2
Tx3
-
Tx IF, Ch3
Rx4
Rx IF, Ch3
Tx4
-
Tx IF, Ch4
Rx5
Rx IF, Ch4
Tx5
-
Tx IF, Ch5
RxBu
Rx IF, Ch Bu
Tx6
-
Tx IF, Ch6
Rx6
Rx IF, Ch5
Tx7
-
Tx IF, Ch7
Rx7
Rx IF, Ch6
Tx8
-
Tx IF, Ch8
Rx8
Rx IF, Ch7
Tx9 (Not Used)
-
-
Rx9 (Not Used)
-
Tx10 (Not Used)
-
-
Rx10 (Not Used)
-
Switch Control
CRS-230
IF Switch Control
-
- -
Once the applicable transponder configuration and cabling has been completed, the
switch is ready for the next procedure, Configuring Automatic Operation Mode.