beautypg.com

Switch, Table 2-11 crs-280 if switch connections, Crs-280 t – Comtech EF Data CRS-400 User Manual

Page 47

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Installation and Setup

MN/CRS400.IOM

31

2.13.2 C

ONFIGURING AND

C

ABLING FOR

M

ULTIPLE

T

RANSPONDERS

,

U

SING THE

CRS-280 T

RANSPONDER

S

WITCH

The CRS-280 provides complete isolation of the IF signals. The redundant Mod/Demod
IF signals are routed to the traffic Mod/Demod IF path when the RMI is online.

Once connected, the CRS-400 automatically senses the presence of the CRS-280. The
CRS-400, upon switching, leaves the offline modulator with its RF on, and the CRS-280
switch relays isolate any undesired signals.

1

Connect the CRS-280 to the CRS-400 with a 25-pin control cable.

2

Refer to Table 2-11 for a complete listing of the CRS-280 IF connections.

3

Connect the Transmit and Receive IF of each Mod/Demod to the CRS-280 with the correct IF
cables.

The same IF connections are used between the CRS-280 and all modems as shown in
Table 2-11.

Table 2-11 CRS-280 IF Switch Connections

From CRS-280

To Other

To Modulator

From CRS-280

To Demodulator

Tx BU

-

Tx IF, Ch Bu

Rx1

Rx IF, Ch1

Tx1

-

Tx IF, Ch1

Rx2

Rx IF, Ch1

Tx2

-

Tx IF, Ch2

Rx3

Rx IF, Ch2

Tx3

-

Tx IF, Ch3

Rx4

Rx IF, Ch3

Tx4

-

Tx IF, Ch4

Rx5

Rx IF, Ch4

Tx5

-

Tx IF, Ch5

RxBu

Rx IF, Ch Bu

Tx6

-

Tx IF, Ch6

Rx6

Rx IF, Ch5

Tx7

-

Tx IF, Ch7

Rx7

Rx IF, Ch6

Tx8

-

Tx IF, Ch8

Rx8

Rx IF, Ch7

Tx9 (Not Used)

-

-

Rx9 (Not Used)

-

Tx10 (Not Used)

-

-

Rx10 (Not Used)

-

Switch Control

CRS-230

IF Switch Control

-

- -

Once the applicable transponder configuration and cabling has been completed, the
switch is ready for the next procedure, Configuring Automatic Operation Mode.