beautypg.com

A.3.5.4 (config, opts) restore-time – Comtech EF Data CRS-400 User Manual

Page 66

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Remote Control

MN/CRS400.IOM

50

A.3.5.4 (CONFIG, OPTS) RESTORE-TIME

RESTORE TIME: [OFF]
OFF/ON SET-TIME (ENT)

RESTORE TIME: [24hr clk]
02:10 (PRESS ENTER)

Note: The RESTORE feature is only active in Auto mode.

If the switch is set for Auto mode and a sustained fault occurs, it will switch to back-up
and stay there until any further fault occurs, or the user intervenes (taking the switches to
Manual and then selecting to switch from backing up to bridging a unit).

Enabling the RESTORE TIME setting allows the switch to automatically restore
operation from backup to the main traffic unit at a selected time, if all the faults are
cleared
.

Select OFF to disable or ON to enable the RESTORE TIME feature and press ENTER. If
RESTORE TIME is ON, set the time (using the 24-hour clock) when the automatic
restoral should occur, and press ENTER.

Note: Set the RESTORE TIME for a time when traffic is low; for example, 2:00 a.m.

If enabled, and in Auto mode, at the RESTORE TIME, the offline traffic unit is
configured to match the configuration of the redundant unit. This is done in case the unit
has come back from repair. It has been activated, but the user may not know the correct
configuration. It is then checked to see that there are no faults. If there are no faults, the
unit is brought online, freeing up the redundant unit.