Data redundancy and controller, 1 data redundancy and controller – Comtech EF Data CRS-400 User Manual
Page 24
CRS-400 1:8 Redundancy Switch
Revision 0
Introduction
MN/CRS400.IOM
8
1.4.1 D
ATA
R
EDUNDANCY
A
ND
C
ONTROLLER
Characteristic Requirement
Number of Prime
Mods/Demods
1 to 8
Number of Backup
Mods/Demods
1
Operating Mode - Data
Switch
Dependent or Independent
Operating Mode - IF Switch
Dependent or Independent
Mod/Demod
Priority/Programmable
1 Bridge Mode
Switching Hold Off Time
2 to 99 Seconds
Switching Manual
or
Auto
Default on Power Loss
Redundant Modulator/Demodulator traffic returns to the normal
traffic path.
Operating Modes
Fully Automatic
Manual, force backup to replace selected traffic channel
Manual, force backup to parallel traffic channel, Bridge
Remove selected traffic channel from control, Active or Not Active
User interface/Connector
(8 Data/TMI Channels)
HSSI to 70 Mbit/s SCSI-2 female
75 Ohm, Supporting :
BNC-Female
Configuration Control
Remote:
EIA-485/232-C,
programmable
Both switch and mod/demod communications
Manual:
Menu driven from switch front panel
Both switch and mods/demods
Tx Offline Activity
Bridged unit receives a copy of the clock and data from one of the
traffic channels. User designates the traffic channel.