beautypg.com

Specifications (preliminary), 4 specifications (preliminary), Pecifications – Comtech EF Data CRS-400 User Manual

Page 23: Reliminary

background image

CRS-400 1:8 Redundancy Switch

Revision 0

Introduction

MN/CRS400.IOM

7

1.4 S

PECIFICATIONS

(P

RELIMINARY

)

Characteristic Requirement

AC Prime Power

Two independent inputs,
90 to 264 VAC; 50/60 Hz;
at 25 Watts

Size/Weight

Data

Switch/Control

Unit

IF Switch Unit

4U 19 in. by 20.1 in. deep, Rack Mount

(4U 48.26 cm W by 51.054 cm D)
< 20 pounds (< 9.07 kg)

4U 19 in. by ~4.5 in. deep, Rack Mount

(4U 48.26 cm W by 11.43 cm D)
< 10 pounds (<4.54 kg)

Environmental

Temperature

Humidity

0 to +40

°

C Operating

-50 to +100

°

C Storage

95% at +40

°

C, Non-condensing

EMC And Safety

EN 55022 Class B emissions
EN 50082-1 immunity
EN 60950 Safety
FCC Part 15 Class B