Table a-1. baud rate switch positions – Comtech EF Data RCS11 User Manual
Page 90
RCS11 1:1 Redundancy Switch
RCS11 DIP Switch Configurations
MN-RCS11 – Revision 9
A–2
Figure A-2. DIP Switch showing Address and Baud Rate
Table A-1 identifies the various S3 dip switch positions. Pins 1 - 6 are utilized for M&C unit
addressing when using multiple switches. Pins 7 & 8 are utilized for baud rate for the terminal or
remote M&C. Address settings are also accessible through the Remote Port (J-20) with the
switch in Terminal Mode. An empty space in Table A-1: represents the (off) position.
Table A-1. Baud Rate Switch Positions
BAUD RATE
SW-1
SW-2
SW-3
SW-4
SW-5
SW-6
SW-7
SW-8
9600
4800
ON
2400
ON