RCS11 1:1 Redundancy Switch

RCS11 Remote Communications

MN-RCS11 – Revision 9

B–8

1 = B Online
2 =


Opcode <2285h>

Command RCS11 Force Manual Backup

Command Data Field (2 bytes):
<1>

Mod Backup State

0 = A online

1 = B online

<1>

Demod Backup State

0 = A online

1 = B online


Opcode <2086h>

Query RCS11 Switch Delays

Query Response Data Field (8 Bytes):
<1>

Switch Delay Mod Fault MSB

<1>

Switch Delay Mod Fault LSB

<1>

Switch Delay Mod NoFault MSB

<1>

Switch Delay Mod NoFault LSB

<1>

Switch Delay Demod Fault MSB

<1>

Switch Delay Demod Fault LSB

<1>

Switch Delay Demod NoFault MSB

<1>

Switch Delay Demod NoFault LSB


Opcode <2286h>

Command RCS11 Switch Delays

Command Data Field (8 Bytes):
<1>

Switch Delay Mod Fault MSB

<1>

Switch Delay Mod Fault LSB

<1>

Switch Delay Mod NoFault MSB

<1>

Switch Delay Mod NoFault LSB

<1>

Switch Delay Demod Fault MSB

<1>

Switch Delay Demod Fault LSB

<1>

Switch Delay Demod NoFault MSB

<1>

Switch Delay Demod NoFault LSB


Opcode <2087h>

Query RCS11 Switch Alarms

Query Response Data Field (5 bytes):
<1>

Global Current Alarm

Bit 0: 1 = Global Alarm

Bit

1..7:

unused,

return

0


<1>

External Current Alarms

Bit 0: 1 = Mod A Alarm
Bit 1: 1 = Force Mod A Alarm
Bit 2: 1 = Demod A Alarm
Bit 3: 1 = Force Demod A Alarm
Bit 4: 1 = Mod B Alarm
Bit 5: 1 = Force Mod B Alarm
Bit 6: 1 = Demod B Alarm
Bit 7: 1 = Force Demod B Alarm


<1>

Switch Current Alarms

Bit 0: 1 = Switch Power 1 Alarm
Bit 1: 1 = Switch Power 2 Alarm
Bit 2: 1 = Switch Firmware Alarm
Bit 3: 1 = Switch NV Alarm
Bit 4: 1 = Switch Internal Alarm
Bit 5..7: unused, return 0


<2>

Spare Current Alarms

Always 0