10.
Photocells for flap scanning
Caution: Risk of injury!
Switch the main switch off.
Adjust the reflected light barriers only with the sewing unit switched
off.
Standard and checking
The light spots 2 and 3 of the photocells 1 and 4 must shine on the
reflected foils of the main clamp.
The light spots must hit the reflected foil approx. 1.5 - 2 mm from the
outside edge.
–
Check whether the light beam of the photocells shines on the
reflected foil.
Correction
–
Loosen the screws at the photocell.
–
Adjust the photocell.
–
Tighten the screws at the photocell.
40
4
3
2
1