Beisler 100-68 User Manual
Page 57
3.6
Flap clamp
3.6.1
Flap clamp position
Caution: Danger of injury!
Switch the main switch off.
Check and adjust the flap clamp only with the sewing unit switched off.
Standard and checking
The flap clamps 2 must have a distance of 5 mm parallel to the inside
of the main clamp 1.
–
Close the flap clamp manually.
–
Check the distance between flap clamp 2 and the inside of main
clamp 1.
Correction
–
Loosen the screws 4.
–
Shift the flap clamp holder 3 correspondingly.
–
Tighten the screws 4.
19
3
2
1
4
3
5 mm