6.6.2.2 Testing the bobbin thread monitor
This program serves for aligning the reflected light barriers of the
bobbin thread monitors.
full
empty
Test with full bobbin
–
Insert a full bobbin.
–
Cover the bobbin thread monitor against extraneous light.
–
Pull the bobbin thread.
–
A value between “0 – 4” should be indicated in the bar graph.
Test with empty bobbin
–
Insert an empty bobbin.
–
Cover the bobbin thread monitor against extraneous light.
–
Turn the empty bobbin until the surface is in parallel position to the
bobbin thread monitor.
–
A value between 8 – 15” should be indicated in the bar graph.
–
Tap the function key ESC to quit the test program.