6.5
Global parameters
The global paramaters comprise the general machine settings.
Alterations will affect all programmed seams.
The following global parameters can be altered:
01 Front feeding point
Distance between feeding position and sewing start.
When the seam length is changed, only the seam end will vary.
Input:
Factory setting:
135 mm
02 Central feeding point
With this setting the seam beginning is calculated in such a way that
seam beginning and seam end are equally shifted when the seam
length is changed.
This is usually required for a hip pocket with dart in case the dart is to
be located in the middle of the pocket.
Input:
Factory setting:
225 mm
03 Rear feeding point
Setting: Distance between feeding position and seam end.
When the seam length is changed, the seam end remains unchanged
and the seam beginning varies.
Input:
Factory setting:
315 mm
04 Folder up after
The time when the folder is swivelled up after sewing.
If the section is set too short, the folder will get caught at the folding
slides.
Input:
Factory setting:
335 mm
23