Configuring Code 128 Bar Codes

1.

To configure Code 128 settings, tap Code 128 from the Scanner
Configuration screen.

2.

Enable each bar code you need to scan.

Code 128

Allows the scanner to scan Code 128 bar codes.

UCC/
EAN-128

Allows the scanner to scan UCC/EAN-128 bar codes.

ISBT 128

Allows the scanner to scan ISBT 128 bar codes. Any
length bar code is valid.

3.

Tap OK to save all the settings and return to the Scanner
Configuration screen.

Configuring I 2of5 Bar Codes

1.

To configure I 2of5 settings, tap I 2of5 from the Scanner
Configuration screen.

2.

Enable each bar code you need to scan.

I 2of5

Allows the scanner to scan I 2of5 bar codes.

Transmit
CD

Tells the scanner to return the check digit with the data
when an
I 2of5 bar code is scanned.

Convert
to
EAN13

Tells the scanner to convert 14-character I 2of5 bar
codes into an EAN13 bar code.

For the conversion to work, the following must occur:
♦ I 2of5 bar codes must be enabled.
♦ 14 must be a valid length.
♦ The data must have a leading zero.
♦ The data must include an EAN13 check digit.

Verify
CD

Tells the scanner to check the integrity of a scanned I 2of5 bar code to ensure it
complies with either USS or OPCC standards.

Lengths
Sets the
length(s)
for I2 of
5 bar
codes.

Variable, specifies that I 2of5 bar codes can be any length.
Note: Specifying a range of lengths increases the likelihood of unsuccessful scans.
1 Fixed, specifies a single length for valid I 2of5 bar codes. The range for Length 1 is
2 – 99. The default is 14.
2 Fixed, specifies two lengths for valid I 2of5 bar codes. The range for Length 2 is 2
– 99. The default is 0.

3.

Tap OK to save all the settings and return to the Scanner Configuration screen.


5-6 System Administrator’s Guide