8.

Set the Supplemental Redundancy, which sets the number of times a symbol without
supplemental information is decoded. The range is
2 – 20. The default is 7.

9.

Set the Security, which is how many times to scan the same barcode to determine a
successful read. The range is 1 – 4. The default is 1.

Before setting this security level, you must decide the print quality of the bar codes you
are scanning. The better the quality of the bar code, the lower the security level
needed.

1

Choose 1 if most of your scans are successful.

2

Choose 2 when your unsuccessful scans are related to characters 1, 2, 7, and 8.

3

Choose 3 when your unsuccessful scans are not limited to characters 1, 2, 7, and 8.

4

Choose 4 if unsuccessful scans still occur at level 2.

10.

Tap OK to save all the settings and return to the Scanner Configuration screen.

Configuring Code 39 Bar Codes

1.

To configure Code 39 settings, tap Code 39 from the Scanner
Configuration screen.

2.

Enable each bar code you need to scan.

Code 39

Allows the scanner to scan Code 39 bar codes.

Transmit
CD

Tells the scanner to return the check digit with the data
when a Code 39 bar code is scanned.

Code32
Prefix

Allows the scanner to scan Code 32 Prefix bar codes.

Convert to
Code32

Tells the scanner to convert Code 39 bar codes to Code 32 bar codes.

Full ASCII
Conversion

Allows the scanner to interpret data in a Code 39 bar code as an ASCII
representation. The scanner does not autodiscriminate between Code 39 and Code
39 Full ASCII.
Note: Do not enable this option and Trioptic Code 39 at the same time.

Trioptic 39

Allows the scanner to scan Trioptic Code 39 bar codes. The length is always 6.
Note: Do not enable this bar code and Code 39 Full ASCII at the same time.

Verify CD

Tells the scanner to check the integrity of all Code 39 bar codes that it scans.
Note: This option only works on Code 39 bar codes that include a modulo 43 check

digit.

Lengths
Sets the
length(s) for
Code 39 bar
codes.

Variable, specifies that Code 39 bar codes can be any length.
Note: Lengths include check digits.
1 Fixed, specifies a single length for valid Code 39 bar codes. The range for
Length 1 is 2 – 99.
The default is 2.
2 Fixed, specifies two lengths for valid Code 39 bar codes. The range for Length
2 is 2 – 99.
The default is 55.
If you have enabled Code 39 Full ASCII, choose Variable.
Note: Specifying a range of lengths increases the likelihood of unsuccessful

scans.

3.

Tap OK to save all the settings and return to the Scanner Configuration screen.

Configuring the Scanner 5-5