beautypg.com

Avery Dennison Platinum 6039 System Administrator Guide User Manual

Page 28

background image

For the On-Demand sensor, hold a white label against the sensor as shown. When you
cover the sensor with a label, the values change on the screen. The valid range is
between 3.0 and 5.0. If the sensor is covered by a black mark, the valid range is
between 0 and 1.5.

On-Demand Sensor
being covered by
label.

4.

The value listed for PH Temperature is the current temperature of the printhead. The valid
range is between 5 and 60 Celsius. The temperature of the printhead depends upon the
number of labels printed and the operating environment. If the temperature is greater than
60, the printer will not print.

5.

Tap Stop to stop the test and clear the values. Tap Start to run the test again.

Note: If the value is not within the ranges, make a note of the values given and call Service.

6.

Tap Back to return to the Print Engine Tests screen.
OR
Tap Done to return to the desktop.

4-6 System Administrator’s Guide