Functional Description
MVME3100 Single Board Computer Installation and Use (6806800M28E)
71
Serial Interface
– One 16550-compatible, 9.6 to 115.2 KBAUD, MPC8540, asynchronous
serial channel for front-panel I/O
– One quad UART controller to provide four 16550-compatible, 9.6 to
115.2 KBAUD, asynchronous serial channels for rear P2 I/O
Timers
– Four 32-bit MPC8540 timers
– Four 32-bit timers in a PLD
Watchdog Timer
– One MPC8540 watchdog timer
VME Interface
– VME64 (ANSI/VITA 1-1994) compliant
– VME64 Extensions (ANSI/VITA 1.1-1997) compliant
– 2eSST (ANSI/VITA 1.5-2003) compliant
– VITA 41.0, version 0.9 compliant
– Two five-row P1 and P2 backplane connectors
– One TSi148 VMEbus controller
Form Factor
– Standard 6U VME
Miscellaneous
– One front-panel reset/abort switch
– Four front-panel status indicators: 10/100/1000 Ethernet link/speed
and activity, board fail, and user software controlled LED
– Six planar status indicators: one power supply status LED, two user
software controlled LEDs, three sATA activity LEDs (one per channel)
– One standard 16-pin COP header
– Boundary scan support
– Switches for VME geographical addressing in a three-row backplane
Software Support
– VxWorks operating system
– Linux operating system
Table 4-2 MVME721 RTM Features Summary
Feature
Description
I/O
– One five-row P2 backplane connector for serial and Ethernet I/O
passed from the MVME3100
– Four RJ-45 connectors for rear-panel I/O: four asynchronous serial
channels
– Two RJ-45 connectors with integrated LEDs for rear panel I/O: one
10/100/1000 Ethernet channel and one 10/100 Ethernet channel
– One PIM site with rear-panel I/O
Table 4-1 MVME3100 Features Summary (continued)
Feature