2.4 Unit Protection

Parameter

Specification

Input Overcurrent:

Electronic current limit with fuse.

Transients:

Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.

Output Overcurrent:

Constant current operation. (Standard)
0.1 Second shutdown (constant voltage mode Option)

Output Short Circuit:

Peak current limit.
Shutdown (constant voltage mode Option).

Overtemperature:

Automatic shutdown.

2.5 Mechanical

Parameter

Specification

Dimensions:

Height

Width

Depth

Unit

13.26

48.26

56.62

cm

5.22

19

22.29

inches

Unit Weight:

2001RP

2001RP-AV

2001RP-LZ

39 Kg / 85 lbs

34 Kg / 76 lbs

39 Kg / 85 lbs

Material:

Steel chassis and panels.
Aluminum cover.

Finish:

Yellow iridite, painted semi-gloss polyurethane

Cooling:

Fan cooled with air intake on the sides and exhaust to the rear.

Internal Construction:

Modular sub assemblies.

Chassis Slides:

P/N 210960 / Option -RMS
General Devices Model CTS-1-20-B307-2

Rear Panel Mounted Connectors:

RS232C I/F

DB 9

IEEE-488 I/F

D-shell 24 pin

Remote Inhibit

BNC (requires -OP1 option package)

Function Strobe

BNC (requires -OP1 option package)

AC Output

Amp 1-480705-1

External Sense

Amp 1-480705-1

Line Input

Kulka 9-85-3 Terminal block