2 specifications, 1 electrical, 2specifications – AMETEK 2001RP User Manual
Page 12

User and Programming Manual - Rev R
2
2001RP
2
Specifications
All specifications at 23
±5°C unless noted otherwise.
2.1 Electrical
Input
Line Voltage:
115 V
RMS
nominal, 103 V
RMS
- 127 V
RMS
AC
230 V
RMS
nominal, 187 V
RMS
- 253 V
RMS
AC
Unit must be configured for correct Line input voltage.
Line Current:
36 A
RMS
maximum, line voltage = 103 VAC, full-load
PF = 0.7, Efficiency = 75%, (typical)
Inrush Current:
185 A
PEAK
at 253 V
AC
input line.
Input power factor:
0.7 at full-load and 103 V
AC
input
Line Frequency:
47 Hz - 400 Hz.
Efficiency:
75% typical (depending on line and load)
Isolation Voltage:
Input to output = 2300 VAC, input to chassis = 1350 VAC.
Output
Parameter
Specification
Voltage
Range
2001RP
0 to 150 V
RMS
or 300 V
RMS
(standard ranges)
(see Section 3.7)
2001RP-AV
115 V and 230 V
or
115 V only (factory set)
2001RP-LZ
135 V and 270 V
Resolution
0.1 volt
Accuracy
± 0.1 % of calibrated range, 45 Hz - 100 Hz
± 0.2 % of calibrated range, 100 Hz - 5000 Hz
Applies from 10 to 100% voltage range.
Below 45 Hz, add 2 %
Load Regulation
0.1 % of FS. Add 0.05% above 2000 Hz