AMETEK 2001RP User Manual
Page 108

User and Programming Manual - Rev R
98
March 2008
2001RP
LIMit:VOLTage?
This command queries the maximum voltage the power source will operate at in the high
voltage range. For 2001RP-AV models configured for single voltage range, only one range is
available. In this case, this command will return the value for the only available voltage
range. The presence of a single range configuration can be derived from the limit value
returned. If the voltage limit value is less than 201 volt, the 2001RP is configured for single
voltage range operation. If a value above 200 volt is returned, the 2001RP has a high and a
low voltage range. On dual range configurations, the maximum voltage in the high range is
returned and this value must be even. The low range value is half that of the high range. On
single voltage range units, the value voltage of the only available range is returned and this
value can be odd or even.
Only the Query format of this command is available to the user.
Command Syntax
LIMit:VOLTage
Parameters
maximum voltage available in high voltage range [command
protected]
Query Syntax
LIMit:VOLTage?
Returned Parameters