beautypg.com

Appendix c: error messages – AMETEK 2001RP User Manual

Page 128

background image

User and Programming Manual - Rev R

118

2001RP

Appendix C: Error Messages

Error Number

Error Message String

Error Causes

0

"No error"

-100

"Command error"

Generally the result of sending a
command that uses incorrect syntax.
This same error may result from the
inability of the AC source to process
successive GPIB non-query commands
sent to it. To avoid this condition, it is
necessary for the application
programmer to insert a 20 msec delay
between commands.

-200

"Execution error"

Generally the result of sending a value
that is out of range, i.e., a VOLT 200
command when the unit is in the 150 V
(Low) range.

-300

"Device specific error"

Generally the result of an over current
(current limit trip) or over temperature
condition.

-350

"Queue overflow"

Generally caused by too many errors
being generated without reading error
status, causing error buffer to overflow.

-400

"Query error"

Generally caused by sending a query
followed by another command without
accepting the query response first.

Table 12-1: Bus Error Messages