3
Parameter
Specification
External Sense
Will compensate for up to 7% of voltage drop up to 2kHz
Line Regulation
0.02 % of FS
Settling time
From start of voltage change from 5.0 V
RMS
or higher
voltage to within 2% of final value:
No load:
16 msec
Full load:
300 msec
(16 msec to within 15 % of final value)
Distortion (THD)
(into linear load, full
power, full scale
voltage)
45-1000Hz
1.0 %
1000-2000Hz
1.5 %
2000-3000Hz
2.0 %
3000-4000Hz
2.5 %
4000-5000Hz
3.0 %
Distortion (THD)
for AV option
(into linear load, full
power, full scale
voltage)
45-1000Hz
2.0 %
1000-2000Hz
3.0 %
2000-3000Hz
4.0 %
3000-4000Hz
5.0 %
4000-5000Hz
6.0 %
DC Offset voltage
AC Coupled transformer output
Output noise
< 0.1 V
RMS
typical
( 20 kHz to 1 MHz at full load )
Temperature
coefficient:
± 0.02 % of full scale per degree C
Stability (24 hours)
± 0.015 % of full scale under constant load, line and
temperature
Total Power
2000 VA maximum at full scale voltage, either range
Current
Range
2001RP
2001RP-AV
2001RP-LZ
150
300
115
230
135
270
Volt Range
13.4
6.7
17.4
8.7
14.8
7.4
A
RMS
44.5
22.2
58
29
49.4
24.7
A
PEAK
Adjustable Limit
0.0 to Maximum available RMS current for selected
voltage range from 50% to 100% of programmed
voltage. For voltage < 50% of range, see V-I derating
chart on next page for available maximum RMS current.
Accuracy
Programmed value + 5, -0 % of maximum RMS current