User and Programming Manual - Rev R

2001RP

3

Parameter

Specification

External Sense

Will compensate for up to 7% of voltage drop up to 2kHz

Line Regulation

0.02 % of FS

Settling time

From start of voltage change from 5.0 V

RMS

or higher

voltage to within 2% of final value:

No load:

16 msec

Full load:

300 msec

(16 msec to within 15 % of final value)

Distortion (THD)

(into linear load, full
power, full scale
voltage)

45-1000Hz

1.0 %

1000-2000Hz

1.5 %

2000-3000Hz

2.0 %

3000-4000Hz

2.5 %

4000-5000Hz

3.0 %

Distortion (THD)
for AV option

(into linear load, full
power, full scale
voltage)

45-1000Hz

2.0 %

1000-2000Hz

3.0 %

2000-3000Hz

4.0 %

3000-4000Hz

5.0 %

4000-5000Hz

6.0 %

DC Offset voltage

AC Coupled transformer output

Output noise

< 0.1 V

RMS

typical

( 20 kHz to 1 MHz at full load )

Temperature
coefficient:

± 0.02 % of full scale per degree C

Stability (24 hours)

± 0.015 % of full scale under constant load, line and
temperature

Total Power

2000 VA maximum at full scale voltage, either range

Current

Range

2001RP

2001RP-AV

2001RP-LZ

150
300
115
230
135
270

Volt Range

13.4

6.7

17.4

8.7

14.8

7.4

A

RMS

44.5
22.2

58
29

49.4
24.7

A

PEAK

Adjustable Limit

0.0 to Maximum available RMS current for selected
voltage range from 50% to 100% of programmed
voltage. For voltage < 50% of range, see V-I derating
chart on next page for available maximum RMS current.

Accuracy