) Pulse outputs (CVM-C10-ITF CVM-C10-MC and CVM-C10-mV)
Maximum frequency
16 impulses / sec
Pulse width
30 ms to 500 ms (Programmable)
Relay outputs
Quantity
2
Max� voltage open contacts
250 V ~
Maximum current
6 A
Maximum switching power
1500 W (AC1)
Electrical life (250 VAC / 5A)
60x10
3
cycles
Mechanical life
10x10
6
cycles
Digital inputs
Quantity
2
Type
NPN Potential free contact
Insulation
optoisolated
Communications
Modbus RTU
BACnet
Bus
RS-485
MS/TP
Protocol
Modbus RTU
BACnet
Baud rate
9600 - 1920
Stop bits
1 - 2
1
Parity
without - even - odd
without
User interface
Display
LCD Custom COG
Keyboard
Capacitive, 3 keys
LED
3 LED
Environmental features
Operating temperature
-5ºC... +45ºC
Storage temperature
-10ºC ... +50ºC
Relative humidity (non-condensing)
5 ... 95%
Maximum altitude
2000 m
Protection degree
IP31
Front panel: IP51 (IP64 with accessory)
Mechanical features
Dimensions ( Figure 26)
96.7x96.7x62.5 mm
Weight
330 gr
Surround
Self-extinguishing V0 plastic
Attachment
Panel
Standards
Safety of electronic measuring units
UNE EN 61010: 2010
Electromagnetic compatibility (CEM)� Part 6-3: Generic standards�
Emission standard for residential, commercial and light industry
environments�
UNE EN 61000-6-3:2007
Electromagnetic compatibility (CEM)� Part 6-1: Generic standards�
Immunity in residential, commercial and light industry environments UNE EN 61000-6-1:2007
Coordination of the insulation of units installed in low voltage sys-
tems (networks)�
IEC 664:2007