20.6 Equipment and Options MKF / MKFT
To operate the alternating climate chamber, use only original BINDER accessories or acces-
sories / components from third-party suppliers authorized by BINDER. The user is responsible
for any risk arising from using unauthorized accessories.
 
Regular equipment 
Microprocessor display program controller with 2-channel technology for temperature and humidity 
Electronically controlled humidifying and dehumidifying system with capacitive humidity sensor *) 
(humidity range, see diagram) 
Integrated freshwater can 
Heated window and interior lighting 
Programmable bedew protection of charging material 
Environmentally friendly refrigerant R404a (MKF / MKFT) and R 23 (MKFT) 
Temperature safety device class 2 acc. to DIN 12880:2007 
Internal socket 230 V AC 230V, 1N ~ 50-60 Hz, max. load 500W, protection type IP 54 
4 zero-voltage relay outputs, addressable via operation lines 
Ethernet interface for computer communication 
1 access port with silicone plug ∅ 50 mm / 1.97 in left (MKF / MKFT 115, 240), 
2 access ports with silicone plug ∅ 80 mm / 3.15 in left and right (MKF / MKFT 720) 
Rack, stainless steel 
Aeration / venting 
Alarm message in case of lack of water inside the freshwater can 
Four castors (2 lockable) 
 
Options / accessories 
Additional rack, stainless steel 
Perforated rack, stainless steel 
Reinforced rack with 1 set of rack lockings 
Securing elements for additional fastening of racks (4 pieces) 
Keyboard locking 
Lockable door 
Safety kit for water connection with hose burst protection device and reflux protection device, pre-
mounted assembly (available via BINDER INDIVIDUAL customized solutions) 
Access ports 30 mm, 50 mm, 80 mm, 100 mm, 125 mm, left or right, with silicone plug 
Over-/under temperature safety device class 2 
Analogue outputs 4-20 mA actual and set-point values for temperature and humidity with 6 pole DIN 
socket, DIN plug included 
Additional measuring channel in the MB1 controller for digital specimen temperature display with flexible 
Pt100 temperature sensor 
Communication interface RS422 
BINDER Data Logger kit for temperature T 220 (chamber values), for temperature / humidity TH 100 
(chamber values) or TH 100/70 (chamber and ambient values) 
Controlled compressed air dryer 
Controlled compressed air dryer particularly suitable for compliance with the common automotive stand-
ards (MKF 720) 
Water cooling (MKF. For MKFT available via BINDER INDIVIDUAL customized solutions) 
Notch-type access port 35 x 100 mm in the door 
BINDER Pure Aqua Service 
Exchange cartridge for BINDER Pure Aqua Service 