Altera DDR Timing Wizard User Manual
Page 84

3–24
Altera Corporation
DDR Timing Wizard User Guide
November 2007
Timing Closure Process
b.
Open the
currently used.
c.
Look for the line:
assign addr_cmd_clk =
If the text on the right-hand side of the "=" sign is either clk or
write_clk
, currently the address/command clock is using the
system clock or write clock, respectively. You can change it to
!clk
or !write_clk, if you need the negative-edge version of
the clock. If you need to use a dedicated PLL output clock
instead, change that text to a different name (for example,
dedicated_addr_cmd_clk
).
1
Remember whether you selected the rising edge or the
falling edge for the address/command active clock edge.
If you are using a dedicated PLL output clock:
i.
Search for the following line in the
rldramii_pll_stratixii
This is the PLL module for the RLDRAM II interface. You
should see code similar to:
rldramii_pll_stratixii
g_stratixii_pll_rldramii_pll_inst
(
.areset (reset),
.c0 (clk),
.c1 (write_clk),
.c2 (addr_cmd_clk),
.c3 (memory_clk_0),
.c4 (memory_clk_1),
.c5 (memory_clk_2),
.inclk0 (clock_source),
.locked (pll_locked)
);
Ensure that the c2 output is connected to
dedicated_addr_ddr_cmd_clk
.