Module Scan Time for all Channels—

Analog

12ms minimum floating point

HART (Typical)

6.4 seconds with 4 variables

12 seconds with 8 variables.

Isolation Voltage

2550VDC terminal block to backplane for 1 second.

2550VDC Channel to Frame Ground for 1 second.

Module Conversion Method

R-Ladder DAC

RTB Screw Torque (NEMA)

7-9 inch-pounds (0.8-1Nm)

Module Keying (Backplane)

Electronic

RTB Keying

User defined

Field Wiring Arm and Housing

20 Position RTB (1756-TBNH or TBSH)1

Environmental Conditions

Operating Temperature

0 to 60°C (32 to 140°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Relative Humidity

5 to 95% noncondensing

Regulatory Compliance

UL 508

CSA (Class 1, Div 2, Group A,B,C,D)

CE compliance to EN 61010-1 and EN 61131-2

FM (Class 1, Div 2, Group A,B,C,D)

Firmware Revision History

Revision No.

Description

1.1

New

2.3

Updated to provide user selectable pass through queue servicing speed.