LINK Systems System 1100 Tonnage Monitor User Manual
Page 36
OPERATION
___________________________________________________________________
2-25
While the keyswitch is in the PROG position the on/off indicator
will flash, indicating that it can be changed. The operator can
turn the decimal point on or off by pressing the ON or OFF keys
respectively.
When the decimal point has been turned on, a decimal point will
automatically appear in all setpoint programming screens and the
machine rating screen.
2.8.11 ALARM CLR
The ALARM CLR screen allows the operator to enable/disable
restrictions on the use of the CLEAR key for clearing alarms and
errors. The alarm clear configuration screen is shown below.
The sample alarm clear screen shown above indicates that the CLEAR
key can be used for clearing tonnage setpoint alarms and errors
while the keyswitch is in any position (BYPASS, RUN, or PROG).
The sample alarm clear screen shown here indicates that the use of
the CLEAR key for clearing alarms and errors has been restricted to
use only while the keyswitch is in the PROG position.
While the keyswitch is in the PROG position the alarm clear access
will flash, indicating that it can be changed. The operator can
toggle between the two alarm clear access settings by pressing the
ENTER key.
2.8.12 MEMORY CLR
The MEMORY CLR function is used to erase the current job setup in
the event of a failure of the non-volatile memory. If the System
ALARM CLEAR ACCESS:
BYPASS/RUN/PROG
ALARM CLEAR ACCESS:
PROG