LINK Systems System 1100 Tonnage Monitor User Manual
Page 113

ERROR CODES
___________________________________________________________________
Error No.
Message / Action
10-10
1)
Check the MACH RATING setting in the Config menu
for correctness.
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
084
Data window 2, channel 1 low setpoint too high.
085
Data window 2, channel 2 low setpoint too high.
086
Data window 2, channel 3 low setpoint too high.
087
Data window 2, channel 4 low setpoint too high.
The Data window 2 low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1)
Check the MACH RATING setting in the Config menu
for correctness.
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
088
Data window 2, channel 1 reverse setpoint too high.
089
Data window 2, channel 2 reverse setpoint too high.
090
Data window 2, channel 3 reverse setpoint too high.
091
Data window 2, channel 4 reverse setpoint too high.
The Data window 2 reverse setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1)
Check the MACH RATING setting in the Config menu
for correctness.
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
092
Data window 2, chan 1 high setpoint < low setpoint.
093
Data window 2, chan 2 high setpoint < low setpoint.
094
Data window 2, chan 3 high setpoint < low setpoint.
095
Data window 2, chan 4 high setpoint < low setpoint.