beautypg.com

LINK Systems System 1100 Tonnage Monitor User Manual

Page 29

background image

OPERATION

___________________________________________________________________

2-18

The access code is entered by using the numeric keypad, then
pressing the ENTER key. If the correct access code is entered, the
screen below will then appear.

Pressing the NO or EXIT keys will leave the alarm counter value in
tact, while pressing the YES key will reset the alarm counter to
zero. The alarm counter screen below is shown after the counter
has been cleared.

2.6.3 STROKE COUNTER

The stroke counter is used to record the total number of machine
stokes since the System 1100 was installed on the machine. The
stroke counter screen is shown below.

The stroke counter can be cleared by pressing the CLEAR key and
then entering a special access code. The stroke counter can be
cleared only while the keyswitch is in the PROG position. Since
the stroke counter is meant to count the total number of strokes
for the machine, it should never be cleared except in the case of
moving the System 1100 to a different machine.

2.7 ERRORS

ENTER ACCESS CODE:
____

CLEAR COUNTER?
(YES/NO)

HIGH-SET ALARMS:
0000000

STROKE COUNT:
0000145267