LINK Systems System 1100 Tonnage Monitor User Manual
Page 116
![background image](/manuals/739096/116/background.png)
ERROR CODES
___________________________________________________________________
Error No.
Message / Action
10-13
117
Data window 4, channel 2 low setpoint too high.
118
Data window 4, channel 3 low setpoint too high.
119
Data window 4, channel 4 low setpoint too high.
The Data window 4 low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1)
Check the MACH RATING setting in the Config menu
for correctness.
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
120
Data window 4, channel 1 reverse setpoint too high.
121
Data window 4, channel 2 reverse setpoint too high.
122
Data window 4, channel 3 reverse setpoint too high.
123
Data window 4, channel 4 reverse setpoint too high.
The Data window 4 reverse setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1)
Check the MACH RATING setting in the Config menu
for correctness.
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
124
Data window 4, chan 1 high setpoint < low setpoint.
125
Data window 4, chan 2 high setpoint < low setpoint.
126
Data window 4, chan 3 high setpoint < low setpoint.
127
Data window 4, chan 4 high setpoint < low setpoint.
The Data window 4 high setpoint of the channel
indicated by the error code is set to a value less
than the low setpoint.
1)
Adjust the high or low setpoint so that the high