SETPTS

$

PEAK

$

MENU

$

DW1 (ON)

$

9

DW2 (ON)
DW3 (OFF)
DW4 (OFF)

REV-SET (ON)
2.0

CH2 21.7 17.9 2.1
CH3 21.9 18.1 2.0
CH4 21.1 17.3 2.2

HI-SET LO-SET
CH1 22.0 18.2
96

To view or edit a group of setpoints, select the desired group
using the up and down arrow keys, then press the ENTER key.
Setpoints for data windows that are turned OFF cannot be viewed or
edited until they are turned ON.

To turn on or off the use of a data window, first move the
keyswitch to the PROG position. Next, select the desired data
window using the up and down arrow keys, then press either the ON
or OFF key.

2.4.1 Editing Setpoints

The Setpoints Editing screen allow the operator to view and edit a
group of setpoints. A group of setpoints consists of a high, low,
and reverse setpoint for each channel. A typical setpoints editing
screen for a four channel System 1100 is shown below.

Because of the limited size of the LCD display, not all setpoints
can be shown at one time. When additional setpoints are located
either above, below, right, or left of the displayed setpoints,
arrows indicating so will appear on the right side of the screen.

While the keyswitch is in the BYPASS or RUN positions the operator
can only view the tonnage setpoint limits. When the keyswitch is
in the PROG position the currently selected setpoint limit will
flash indicating that it can be changed. To change a setpoint,
first select it using the up, down, left, and right arrow keys,