LINK Systems System 1100 Tonnage Monitor User Manual
Page 112
ERROR CODES
___________________________________________________________________
Error No.
Message / Action
10-9
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
072
Data window 1, channel 1 reverse setpoint too high.
073
Data window 1, channel 2 reverse setpoint too high.
074
Data window 1, channel 3 reverse setpoint too high.
075
Data window 1, channel 4 reverse setpoint too high.
The Data window 1 reverse setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1)
Check the MACH RATING setting in the Config menu
for correctness.
2)
Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
076
Data window 1, chan 1 high setpoint < low setpoint.
077
Data window 1, chan 2 high setpoint < low setpoint.
078
Data window 1, chan 3 high setpoint < low setpoint.
079
Data window 1, chan 4 high setpoint < low setpoint.
The Data window 1 high setpoint of the channel
indicated by the error code is set to a value less
than the low setpoint.
1)
Adjust the high or low setpoint so that the high
setpoint is greater than the low setpoint.
080
Data window 2, channel 1 high setpoint too high.
081
Data window 2, channel 2 high setpoint too high.
082
Data window 2, channel 3 high setpoint too high.
083
Data window 2, channel 4 high setpoint too high.
The Data window 2 high setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.