OPERATION

___________________________________________________________________

2-5

ERROR 40 - End Of Cycle cam failure, the CLEAR key can be pressed
to clear the alarm or error.

2.1.2.7 CONTRAST key

The CONTRAST key is used to adjust the contrast of the LCD
display. The display can be adjusted brighter or dimmer by
holding down the CONTRAST key then pressing the up or down arrow
keys respectively. If the keys are held down this function will
automatically repeat to avoid having to repeatedly press the keys
for large adjustments.

2.1.2.8 HIGH SET and LOW SET keys

The HIGH SET and LOW SET keys are used to display the high and low
setpoints on the tonnage displays. The setpoints will be displayed
as long as the key remains depressed.

2.1.3 Mode Selector Keyswitch

The Mode Selector Keyswitch is a three position keyswitch. The key
can only be removed in the RUN position.

RUN - This is the normal operating mode of the System 1100.
When the key is in this position, the operator can only view
setpoint limits, and counter information. Tonnage setpoint
limits and counter limits and count values cannot be altered
or cleared.

PROG - This is the program mode of the System 1100. When the
key is in this position, tonnage setpoint limits can be
changed or turned off, setups can be stored, recalled or
removed, and counter limits can be changed, turned off, and
count values cleared.

BYPASS - This mode is intended for use while die setting.
While in Bypass mode all high, low, and reverse setpoint
alarms are turned OFF. Only machine rating alarms are active
while in bypass mode.

2.2 Menu Selection

The LCD (Liquid crystal display, at the right-top of the operator