LINK Systems System 1100 Tonnage Monitor User Manual
Page 109
![background image](/manuals/739096/109/background.png)
ERROR CODES
___________________________________________________________________
Error No.
Message / Action
10-6
This error results from a failure of the non-
volatile memory.
1)
If the setup has been previously stored in
backup memory, go to the Sto/Rcl menu and recall
the setup.
If the setup is not present in backup memory,
use the CLR MEMORY option in the Config menu to
erase the current job setup. Follow the steps
outlined in section 2.8.12.
046
Config data is corrupt.
This error results from a failure of the non-
volatile memory.
1)
Go to the Config menu and re-enter all of the
configuration parameters (MACH RATING, MACH
NUMBER, THRESHOLD, CAM ZERO, DATA WINDOW, AUTO
SETUP, MACH SPEED, TOPSTOP TMR, DECIMAL PT, and
ALARM). Refer to sections 2.8.2 through 2.8.12
for instructions on setting each parameter.
Note that certain parameters are considered
essential for proper operation of the System
1100 and will be marked with an asterisk (*) in
the lower left corner of their configuration
screens until reset by the operator.
047
Failure of A/D converter.
This error indicates a fault in the analog to
digital converter in the System 1100 Logic Unit.
1)
The Logic Unit Logic board must be replaced to
correct this error.