beautypg.com

Kipp&Zonen LOGBOX SD Data Logger User Manual

Page 15

background image




15

8

CONNECTING MULTIPLE SENSORS DIFFERENTIAL


This configuration allows you to connect up to 3 sensors on the analog input 1-6 which have
an output up to 2500mV.

-AIN1 & AIN2 (first sensor)
-AIN3 & AIN4 (second sensor)
-AIN5 & AIN6 (third sensor)

And it’s possible to connect up to two sensors on the analog inputs 7 and 8 which have an
output up to 3000mV. (Only 12 bits, 3V range)

-AIN7 & GND
-AIN8 & GND

Please note that AIN7 and AIN8 can only be used to connect sensors which have a slightly
higher voltage output up to 3Vdc (Like our UVS sensors) or for 10K thermistors.

How to configure the software will be explained in chapter 14