Troubleshooting

286

FG-750

LED Indicators Description

LED Indicators Description

The LEDs on your unit help you determine its current status. They are
located on the front panel.

For the power and system LEDs, if more than one error is detected at the
same time, the color of the LED will be set according to the most severe
error (red as the most severe, followed by yellow).

The table below presents the possible statuses once the initial startup
sequence is complete.

LED

Status

Meaning and Possible Solution

Power

Green

The unit is on and there are no voltage

problems.

Yellow

Non-critical voltage error detected. You can look

in the Host Web UI for more information

(see Viewing System Status on page 290).
One of the power supply module could be

missing or defective.

Ensure that both power supply modules are

present and functioning properly. If necessary,

replace the defective power supply

(see Replacing the Power Supply Modules on

page 257).
If the problem persists, contact EXFO.

Red

Critical voltage error detected.
Contact EXFO.

Off

The unit has been disconnected from all its

power sources.