Operating Your RTU in OTDR Measuring Mode

Fiber Guardian

147

Managing Optical Routes

Test on Demand: This type of test is conducted to check the health
of fibers when required.

You can view, add, modify, and delete test setups.

There are three types of tests. If you select Proactive maintenance, the
results of the tests will always be saved.

If you select Monitoring, the results will be saved only if they contain
fault information.

If you select Test on Demand, the Server Data Upload section and
Targeted count per cycle field in the Learning section get disabled.

You can select the high-resolution feature to obtain more data points
per acquisition. This way, the data points will be closer to each other,
which will result in a greater distance resolution for the trace.