Operating Your RTU in OTDR Measuring Mode

Fiber Guardian

191

Managing Cable Templates

5. Define the test setup parameters as follows:

5a. Select the Test Setup tab.

5b. Enter the parameters according to your needs.

I

MPORTANT

EXFO does not recommend to test in high resolution if the
acquisition time is less than 15 seconds. It may be impossible to
obtain acceptable performance with this combination of settings.

To use default threshold sets or

your own threshold sets

(see Managing Threshold Sets on

page 162)

Test wavelength (one wavelength per template).
Fiber code is indicated between parentheses.

To define the fault detection

parameters manually

To specify which data will be

transferred to the server

(not used with stand-alone RTU)