Defining default values for system parameters – EXFO FG-750 User Manual
Page 149
Setting Up Your RTU
Fiber Guardian
135
Managing System Setting Values
Defining Default Values for System Parameters
You can define “global” parameters such as the number of test setups that
will be created automatically, the way fiber breaks will be managed, the
maximum database size, etc.
You can specify which data will be uploaded to the EMS server (not
applicable when RTU is used in stand-alone mode).
The table below shows which information will be stored on RTU and
uploaded to the server, in each case.
Degraded fiber handling strategy, when enabled, skips an optical route
if the fiber is degraded. The selection for this option is enabled, by
default.
The maximum number of fiber result entries is 5 000, by default. You
can increase this number up to 100 000 entries. However, this
maximum value will never be reached if the database size exceeds
80% of the maximum database size.
Type of upload
Faults and data
acquired during the
very first reference
or the learning
period
Data acquired with
Monitoring
Data acquired with
Proactive
maintenance
Normal
Uploaded
Not stored
Stored
Uploaded
TRC binary
Uploaded, along with
.trc file
Not stored
Stored
Uploaded, along
with .trc file
No upload
Uploaded
Not stored
Stored
Not uploaded