Configuration (h.248/megaco), Call mode, Test length – EXFO EXpert VoIP Test Tools User Manual
Page 44: Call information
Test Setup
38
EXpert VoIP Test Tools
Configuration (H.248/Megaco)
Configuration (H.248/Megaco)
From the Main Menu, tap H.248/Megaco and the Configuration tab.
Call Mode
Make Call (default): The Caller establishes a control communications
channel with the Receiver. By default, Make Call is selected.
Answer Call: It is the endpoint, which initiates its own stream to the
Caller test set.
Test Length
Select the test length.
Media Duration (sec) is the length of time the test will run in seconds:
1 to 600 seconds (default is 10 seconds).
Number of Packets is the number of RTP packets to exchange
between the controller and the responder: 2 to 65535 (default is 500).
Call Information
Media Type
Live Call (default) specifies that actual call is established between
the Caller and the Callee.
Synthesized Media specifies that the EXpert IP Test Tools
application automatically generates a randomly RTP data.
Codec selects the audio Codec (packet interval, payload size, and IP
bandwidth) used to transmit audio data within the RTP stream.
For Live Call media type: G.711 μlaw (default), and G.711 aLaw.
For Synthesized Media type: G.711 μlaw (default), G.711 aLaw, G.722,
G.723.1, G.726, G.728, G.729, G.729A, G.729B, and G.729AB.